[ Care and Use ManUal ]
IC-Pak Column and Guard Column 1
Contents
I. IntroduCtIon
II. InstallatIon
III. eluent and sample guIdelInes
IV. operatIon
V. Care and maIntenanCe
VI. orderIng InformatIon
VII. Warranty/serVICe
IC-pak Column and guard Column
I. IntroduCtIon
Waters IC-Pak™ anion (A) and cation (C) columns are designed for use
in Ion Chromatography (IC) applications to separate ions.
a. Anion Columns
The stainless steel anion columns separate and quantify many
anions, such as F
-
, CI
-
, NO
2
-
, Br
-
, NO
3
-
, HPO
4
2-
, and SO
4
2-
anions at
ppb levels. Table 1 lists the characteristics of IC-Pak anion columns.
Table 1: Anion Column Characteristics
The packing material is a polymethacrylate resin with a quaternary
ammonium functional group. The columns are shipped in 1.3 mM
gluconic acid/1.3 mM boric acid (pH 8.5).
b. Cation Columns
The non-metallic cation columns separate and quantify Li
+
, Na
+
,
NH
4
+
, K
+
, Mg
2+
, Ca
2+
, Sr
2+
and Ba
2+
cations at ppb levels. The Waters
cation guard column, placed in the solvent stream before the
sample injector, is used only to aid monovalent cation detection by
removing polyvalent cations from the solvent stream.
Table 2 lists the characteristics of IC-Pak cation and cation guard
columns.
Anion Column Dimensions Particle Size Capacity
IC-Pak A 4.6 x 50 mm 10 µm 30 ± 3 µeq/mL
IC-Pak A HC
(High Capacity)
4.6 x 150 mm 10 µm 30 ± 3 µeq/mL
IC-Pak A HR
(High Resolution)
4.6 x 75 mm 6 µm 30 ± 3 µeq/mL
Vedere la pagina 0
1 2 3 4 5 6 7 8 9 10

Sommario

Pagina 1 - [ Care and Use ManUal ]

[ Care and Use ManUal ]IC-Pak Column and Guard Column 1ContentsI. IntroduCtIonII. InstallatIonIII. eluent and sample guIdelInes IV. operatIonV

Pagina 2

[ Care and Use ManUal ]Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.comIC-Pak Column and

Pagina 3

[ Care and Use ManUal ]IC-Pak Column and Guard Column 2Table 2: Cation Column CharacteristicsThe packing material is a styrene divinylbenzene resin wi

Pagina 4

[ Care and Use ManUal ]IC-Pak Column and Guard Column 3To replace a fitting:1. Use a sharp razor blade to make a long tapering cut in the tubing as s

Pagina 5

[ Care and Use ManUal ]IC-Pak Column and Guard Column 4Solvents Containing SaltsChangeover between an organic solvent and water containing salts shoul

Pagina 6

[ Care and Use ManUal ]IC-Pak Column and Guard Column 53. Fill to the mark with Milli-Q water and mix thoroughly. Concentrate may be stored for up to

Pagina 7

[ Care and Use ManUal ]IC-Pak Column and Guard Column 6Temperature:* Do not exceed a flow rate of 1.0 mL/min for the IC-Pak A HR column. Flow rates hi

Pagina 8

[ Care and Use ManUal ]IC-Pak Column and Guard Column 7The following sample equation shows how these weights were determined:1 g CI -/L x 58.44 g Na

Pagina 9

[ Care and Use ManUal ]IC-Pak Column and Guard Column 85. Fill the flask to the mark with 18 megohm water. Tables 8 and 9 contain the species concent

Pagina 10

[ Care and Use ManUal ]IC-Pak Column and Guard Column 9V. Care and maIntenanCea. TroubleshootingTable 11: Column Problems and Solutionsb. Column Stora