[ Care and Use ManUal ]
Analytical Columns and Cartridges 1
Contents
I. IntroduCtIon
II. start-up test proCedure
a. Measuring Intrument Band Spreading
b. Installing the Cartridge or Column
c. Equilibrating the Column
d. Testing the Column Efficiency and Calculating Column Backpressure
III. narrow-bore Columns
IV. Column maIntenanCe
a. Caring for the Column
b. Cleaning and Regenerating the Column
c. Storing the Column
V. troubleshootIng
VI. orderIng and addItIonal InformatIon
analytICal Columns and CartrIdges
I. IntroduCtIon
Waters offers a large selection of analytical columns and cartridges
packed with silica-based packing materials. Follow this instruction
sheet to obtain the best performance, reproducibility, and longevity
from your analytical columns and cartridges. Waters silica-based
materials are packed in:
Steel and PEEK
TM
(polyetheretherketone) Columns — The steel
analytical columns are durable and highly efficient. PEEK
columns are used with nonmetallic systems.
Steel Cartridge Columns — The cartridge columns feature reus-
able end fittings that permit you to replace the cartridge quickly
and easily without tools.
Polyethylene Radial-Pak™ Column Segments — The Radial-Pak
column segments (also referred to as Radial-Pak cartridges)
employ Waters patented technology to improve efficiency
by eliminating the wall effect and voiding common to rigid
columns.
Vedere la pagina 0
1 2 3 4 5 6

Sommario

Pagina 1 - [ Care and Use ManUal ]

[ Care and Use ManUal ]Analytical Columns and Cartridges 1ContentsI. IntroduCtIonII. start-up test proCedure a. Measuring Intrument Band Spreading

Pagina 2

[ Care and Use ManUal ]Analytical Columns and Cartridges 2II. start-up test proCedureFollow the four step start-up procedure for successful operation

Pagina 3

[ Care and Use ManUal ]Analytical Columns and Cartridges 3b. Installing the Cartridge or ColumnFor Column Installation: Connect the column with the di

Pagina 4

[ Care and Use ManUal ]Analytical Columns and Cartridges 4A second effect, called dwell volume is observed with gradient analy-sis. In this case, the

Pagina 5

[ Care and Use ManUal ]Analytical Columns and Cartridges 5c. Storing the ColumnFor Column and Cartridge Columns: Leaving the column unused for less th

Pagina 6

[ Care and Use ManUal ]Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.comAnalytical Column

Commenti su questo manuale

Nessun commento